- MINI SAFETY BREAKER
- MCB TNB1-32G
- RCCB TNB1L-32
- RCCB TRL-40
- RCBO TNB1L-32G
- IP68 RCBO TNB1L-32GW
- ENCLOSURE FOR MINI SAFETY BREAKER
- TR Series Al/Cu UNIVERSAL TERMINAL BLOCK
- 16mm2 Al/Cu universal terminal block
- 50mm2 Al/Cu universal terminal block
- 95mm2 Al/Cu universal terminal block
- 150mm2 Al/Cu universal terminal block
- 240mm2 Al/Cu universal terminal block
- Terminal shroud for TR series Al/Cu universal terminal block
MCCB TRMF4(250A) 4P
-
Share:
TRM MCCB
1.Small size, high capacity;
2.Rated current have fixed type and adjustable type(0.8In-1.0In);
3.Modular structure design, better performance;
4.Ics=100% Icu(Except single pole MCCB);
Description
TRM series circuit breakers and auxiliaries comply with the following international standard:
IEC/EN 60947-1: Low-voltage switchgear and controlgear-Part 1: General rules
IEC/EN 60947-2: Low-voltage switchgear and controlgear-Part 2: Circuit breakers
TRM series MCCB (Standard use environment for TRM series MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;
Classification:
According to the poles: 1-pole, 3-poles, 4-poles
According to the breaking capacity: S-type, H-type
According to the rated current: Fix type, Adjustable type(08In-1.0In)
Technical
Frame size | TRMF4(250A) | ||||||
Breaking capacity code | S | H | |||||
Product code and pole | 1P | 3P | 4P | 1P | 3P | 4P | |
TRMF4-S1 | TRMF4-S3 | TRMF4-S4 | TRMF4-H1 | TRMF4-H3 | TRMF4-H4 | ||
Rated current,In(A) | 100A, 125A, 160A, 180A, 200A, 225A, 250A | ||||||
Adjustable part | Rated current setting(0.8In~1.0In) | X | √ | √ | X | √ | √ |
Lockup device for operating handle | X | √ | √ | X | √ | √ | |
Rated operational voltage,Ue(V),AC50/60Hz | 240V/415V | ||||||
Rated insulation voltage,Ui(V) | 1000V | ||||||
Rated impulse withstand voltage,Uimp(kV) | 8kV | ||||||
Standard | Conformity with IEC/EN 60947-2 | ||||||
Rated frequency(Hz) | 50/60Hz | ||||||
Rated short-circuit breaking capacity,Icu(kA) | |||||||
AC | 240V | 25kA | 50kA | 36kA | 65kA | ||
415V | - | 37kA | - | 50kA | |||
Ics=%*Icu | 50% | 100% | 50% | 100% | |||
Mechanical life(circle) | 7000 | ||||||
Electrical life(circle) | 1000 | ||||||
Dimension Length*Width*Height(mm)
|
1-pole | 150mm*38mm*60mm | |||||
2-poles | - | ||||||
3-poles | 165mm*105mm*60mm | ||||||
4-poles | 165mm*140mm*60mm |
Built-in accessory:
Built-out accessory:
Send Inquiry
Please feel free to contact with us at bruce.lee@hiselec.com or filling up an enquiry form instructed at the bottom, You will get an effective response within 24 hours from Our sales representative. Thanks for your valued time with interest!