- MINI SAFETY BREAKER
- MCB TNB1-32G
- RCCB TNB1L-32
- RCCB TRL-40
- RCBO TNB1L-32G
- IP68 RCBO TNB1L-32GW
- ENCLOSURE FOR MINI SAFETY BREAKER
- TR Series Al/Cu UNIVERSAL TERMINAL BLOCK
- 16mm2 Al/Cu universal terminal block
- 50mm2 Al/Cu universal terminal block
- 95mm2 Al/Cu universal terminal block
- 150mm2 Al/Cu universal terminal block
- 240mm2 Al/Cu universal terminal block
- Terminal shroud for TR series Al/Cu universal terminal block
ELCB TREF1(63A) 2P
-
Share:
TRE ELCB
1.Small size, high capacity;
2.Rated current have fixed type and adjustable type(0.8In-1.0In);
3.Modular structure design, better performance;
4.Ics=100% Icu;
Description
TRE series circuit breakers and auxiliaries comply with the following international standard:
IEC/EN 60947-1: Low-voltage switchgear and controlgear-Part 1: General rules
IEC/EN 60947-2: Low-voltage switchgear and controlgear-Part 2: Circuit breakers
TRE series ELCB(Standard use environment for TRE series ELCB)
1. Ambient temperature: Within the range of -5ºC--+40ºC(However, the average for the duration of 24 hours must not exceed 35ºC);
2. Altitude: 2000m or less
3. Installation class: III
4. The magnetic field near the instalation site should not be more than five times the earth magnetic field in any direction.
5. Pollution: II
Classification:
According to the poles: 2-poles, 3-poles
According to the breaking capacity: S-type, H-type
According to the rated current: Fix type, Adjustable type(08In-1.0In)
According to the trip action time: Fix type, Adjustable type(0.1s/0.3s/0.5s or 0.45s/1.0s/2.0s)
According to the rated residual current: Fix type, Adjustable type(30mA/100mA/300mA/500mA)
Technical
Frame size | TREF1 (63A) | ||||
Breaking capacity code | S | H | |||
Type and pole | 2P | 3P | 2P | 3P | |
TREF1-S2 | TREF1-S3 | TREF1-H2 | TREF1-H3 | ||
Protective function | Overload & Short-circuit & Ground fault | ||||
Rated current ,In (A) | 15A, 20A, 30A, 40A, 50A, 63A | ||||
Rated residual current | Operating ,IΔn (mA) | 30mA, 50mA,100mA,200mA,300mA,500mA | |||
Non-operating ,IΔno (mA) | 15mA,25mA,50mA,100mA,150mA,250mA | ||||
Adjustable part | Rated current setting(0.8In~1.0In) | √ | √ | ||
Lockup device for operating handle | - | √ | - | √ | |
Residual current setting, IΔn | 30mA / 100mA / 300mA / 500mA | ||||
Trip action time setting | 0.1s / 0.3s / 0.5s | ||||
Rated operational voltage ,Ue (V) ,AC 50/60 Hz | 240V/415V | ||||
Rated insulation voltage ,Ui (V) | 1000V | ||||
Rated impulse withstand voltage ,Uimp (KV) | 8kV | ||||
Residual current off-time at IΔn ,Sec (s) | 0.1s | ||||
Standard | Conformity with IEC / EN 60947-2 | ||||
Rated frequency (Hz) | 50/60 Hz | ||||
Rated short-circuit breaking capacity ,Icu (KA) | |||||
AC | 240V | 14kA | 25kA | ||
415V | 5kA | 7.5kA | |||
Ics=%*Icu | 100% | ||||
Mechanical life (circle) | 8500 | ||||
Electrical life (circle) | 1500 | ||||
Dimension Length*Width*Height(mm) |
2-pole | 100mm*50mm*60mm | |||
3-pole | 100mm*75mm*60mm | ||||
4-pole | - |
Built-in accessory:
Built-out accessory:
Send Inquiry